Sprinkler heads not defined in the drawing or no 3D block assigned for a sprinkler head. Going to Navis only - corrupt Persistent Model drawing? eKeyNotFound Dialog box HydraCAD
Sprinkler heads not defined in the drawing or no 3D block assigned for a sprinkler head. Going to Navis only - corrupt Persistent Model drawing?
1. Run checkups before raising to 3D (LCH command)
2. Rebuild HydraCAD layers (RBL command)
3. Make sure sprinkler heads are defined (eg. blue boxes in ACC1 layer)
4 If the user is using plugs, no 3D block has been assigned to its blue box in ACC1. Edit the BLKRDEF1 block for the plug by adding a value to the 3D_HEAD_BLOCK line. Use 3dHSW, 3dPEN or 3dUPR to represent a sidewall, pendent or upright respectively.
5. Delete the Persistent Model drawing, then reexport to Navis. GAB 9/30/14 GAB 11/08/15 JB 12/4/15