Need to save a card for later?
Create a bookmark folder in your browser of choice (Chrome, Firefox...), and save individual cards in your bookmarks to view here later.
AutoCAD Based Calculations (Ribbon/Toolbar/Location)
Description:
Runtime Error 5 1.A.1
Resolved in: 55
Causes:
1. Happens the first time when switching between an Imperial and a Metric calc, or vice-versa. User has not pushed the Sizing button
2. User has no caps on drawing, which makes it hard for AutoCalc to find its way through the piping
3. User had a number in the 3/4 spot in the tree schedule
4. Supply point is not on a deadend pipe
Solutions:
1. Pick the sizing button just once when using a 'new' unit system (not needed again unless switching unit systems again)
2. Add some caps (fixed in current version)
3. Put number in 1" instead of 3/4"
4. Place supply point on a deadend pipe.