Hydratec Inc.

Need to save a card for later?

Create a bookmark folder in your browser of choice (Chrome, Firefox...), and save individual cards in your bookmarks to view here later.

AutoCAD Based Listing (Ribbon/Toolbar/Location)

Button: Start Autolist

Description:

DAO server error

Solutions:


1.
Cause:

CAUSE #2

User does not have administrator rights

Solution:

2) Make sure the user has administrator rights if this does not work...

Right click on the program icon, select "run as administrator." (if this seems to work then..) right click the program icon, pick properties pick the "advanced" button select "run as administrator"


2.
Cause:

CAUSE #3

User had no hangers set up in Assembly.mdb

Solution:

3) Open HydraLIST > General Data > Assembly Table. Check for existing hangers - If none replace file. At least one hanger assembly is required. C:\HES\Hydlist\Ver50\Data\Setup


3.
Cause:

CAUSE #1

HES or a file inside is "read only"

Solution:

1) Right-click the HES folder, pick properties, uncheck read only and hidden. Apply to all subfolders and files.

Updated: March 18, 2024, 2:52 p.m. Created: March 1, 2019, midnight