AutoCAD Based 3D Modeling (Ribbon/Toolbar/Location)

Button: Switch To Edit Mode

Description:

Hydrapipe - vertical pipe issue Switching to Edit Mode leaves HydraPipes in Hydrapipe layer. Then when trying to show system model you get an AutoCAD message box "Please Switch to Edit Mode. Then try again." Switch to Edit....

Solutions:

Cause:

Hydrapipe - vertical pipe issue Switching to Edit Mode leaves HydraPipes in Hydrapipe layer. Then when trying to show system model you get an AutoCAD message box "Please Switch to Edit Mode. Then try again."

Solution:

1. Pick the autocad Properties button

 

2. Pick the Quick Select button (the funnel)

 

3. Set the quick select dialog box to look for: Object type -- HYDRAPIPE Properties -- VerticalPipe_Status Value -- Normal Pick the OK button - then pick the delete button on the keyboard.