Hydratec Inc.

Need to save a card for later?

Create a bookmark folder in your browser of choice (Chrome, Firefox...), and save individual cards in your bookmarks to view here later.

AutoCAD Based Listing (Ribbon/Toolbar/Location)

Button: Start Autolist

Description:

No error , main tagged as welded fab gets listed as threaded material with an Auto Line Number inserted at a riser nipple where the main changes elevation. not listed missing as a line in lines listed as threaded auto line tag autoline tag auto tag none

Solutions:

Cause:

Example: Pieces of Main D are missing from the HydraLIST Mains input & those pieces appear in the Lines input as line #41. An Auto Line Tag for Line #41 was inserted at a riser nipple along Main D

Solution:

Right click on the Riser Nipple and pick properties. Look at the "COMMON PIPE INFO" - "Line_Main" value. If it is set to LINE pick that property and change the value to "MAIN". Rerun the AutoLIST process to create the correct welded fabrication HydraLIST input.

Updated: Jan. 29, 2024, 3:21 p.m. Created: March 1, 2019, midnight