AutoCAD Based HydraCAD Residential (Ribbon/Toolbar/Location)
Description:
This job has gone 200 passes... then error at Step 1a.9 attaching elevation of ... to reference point MTR Step 1A.9, 200 Passes
1. on a multi-level structure, one or more levels do not have any floor to floor connections connecting them to the other levels.
2. 0 length 2 head calculation line inserted on a fitting
3. Supply pipe input has a missing or blank ref. point
1. add floor to floor connections.
2. Erase the 0 length line - hint: there will be a green diamond directly over a fitting or head.
3. Go back to Supply Pipe Input and add the reference point.