AutoCAD Based Listing (Ribbon/Toolbar/Location)

Button: Start Autolist Error Type: Fatal Error

Description:

When attempting to 'Start AutoLIST' (SAL command), user gets an AutoCAD Fatal Error.

 

Solutions:


1.
Cause:

SAL command doesn't like the configuration of;  line pipe --> armover vertical pipe --> armover pipe --> sidewall head

Solution:

Using the CRN command or by editing the vertical pipe (double-click), change the type of vertical pipe from ARMOVER to LINE.  Then change the green armover pipe to the yellow lines layer.


2.
Cause:

Create 3D model without showing fittings will not cause the error.  Using Show Fittings in Model give the Fatal Error.

Layout was setup as, Branchline > armover pipe > sidewall.  The armover diameter was 1/2" diameter

Solution:

Either remove the armover pipe and move the sidewall to the branchline, or change the diameter of the armover pipe to 1".

(Thanks Matt K!)


3.
Cause:

More than one sprinkler head being fed by a green pipe

 

Solution:

In this case we cannot use green pipe (SPRKDAT4) here.

 


4.
Cause:

Similer to the side outlet to a sidewall, this one was to a plug

 

Solution:

Change the SPRKDAT4 pipe's layer to SPRKDAT2


5.
Cause:

Armover piping is connected directly to main piping

 

Solution:

Armover piping should only be connected to branchline piping (SPRKDAT4 to SPRKDAT2). 

 

If you have a vertial pipe, make sure its properties are corrected as well

 